Description

 

May be used in those states where codes do not restrict solids size in effluent systems.

Features:

  • Float operated, submersible (NEMA 6) 2-pole mechanical switch
  • Durable cast construction, ASTM Class 25 cast iron, switch case and pump housing
  • Cast iron base on models 267 and 268
  • Engineered plastic base on model 266
  • Non-Clogging Vortex Impeller Design. Engineered plastic impeller with metal inserts on models 266, 267 & 268 (1 PH).
  • Not affected by materials normally found in drainage and sewage pumps
  • Stainless steel screws, bolts, handle, guard and arm and seal assembly
  • Neoprene square ring & gasket
  • Oil-filled, hermetically sealed motor
  • Oil lubricated bearings
  • Carbon and ceramic shaft seal
  • Passes 2" spherical solids
  • 2" NPT discharge
  • On point: 12" (automatic units); Off point: 4" (automatic units)
  • Corrosion resistant powder coated epoxy finish
  • Completely submersible
  • Watertight and dust tight
  • Automatic reset thermal overload protection (1 Phase only)
  • Reserve powered design. For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump.

 

Specs

 

Type:

Automatic

Application:

Sewage

Sewage Waste Transfer

Effluent

Material:

Cast Iron

Horse Power:

1/2

Voltage:

115V

Amperage:

10.4

Phase:

1

RPM:

1725

Cord Length:

10'

Cord Type:

UL Listed, 3-Wire Neoprene Cord & Plug

Height:

14-9/32"

Features:

w/ Plastic Impeller

Flow at 5 FT Head:

128 GPM

Flow at 10 FT Head:

89 GPM

Flow at 15 FT Head:

50 GPM

Approvals:

UL/CSA

Weight (lbs):

47.5 lbs

Discharge:

2"

Solids Size:

2"

Shutoff Head (ft.):

21.5'

 

 

Product Details

 
Brand   ZOELLER     Manufacturer Part Number M267
HP 1/2
Rated Voltage    115V AC
Phase - Pumps   1
Amps   10.40
Motor Type   Hermetically-Sealed; Oil-Filled
Body Material     Cast Iron
Impeller Material   Thermoplastic
Shaft Seal Material - Pumps    Carbon; Ceramic
Switch Actuation     Vertical Float
Switch Electrical Connection   Integral
On Point   12 in
Off Point  5 in
Flow Rate @ 10 Ft. of Head   85 gpm
Flow Rate @ 15 Ft. of Head   45 gpm
Flow Rate @ 20 Ft. of Head   10 gpm
Max. Diameter Solids   2 in
Min. Sump Pit Dia.   18 in
Body Dia.   13-1/16 in
Overall Height   14-9/32 in
Cord Length   10 ft
Discharge   2 in FNPT
Max. Liquid Temp.   130 °F
Max. Head   21.5 ft
Duty Cycle   Continuous
Thermal Protection   Yes
RPM   1,725 RPM
Agency Compliance   CSA Certified; UL Listed
Manufacturers Warranty Length   3 yr
UNSPSC   40151517
Country of Origin   USA (subject to change)

 

 

Understanding the M267's Higher-Capacity Role

 

M264 vs. M267: Sizing Up

 

  M264 "Waste-Mate" (4/10 HP) M267 (1/2 HP)
Amps 9.4 10.4
Flow @ 10 ft head 85-89 GPM
Flow @ 15 ft head 45-50 GPM
Shutoff head 21.5 ft
Solids handling 2" 2"
Duty cycle Standard Continuous
Warranty 3 years 3 years

 

The M267's higher horsepower and continuous duty rating make it the better choice when your ejector system needs to push wastewater a greater vertical distance to reach the sewer connection, or when demand is higher (multiple bathrooms, higher fixture count) than a standard single-bathroom basement setup.

 

Why "Head" Matters More Than You'd Expect

 

The flow rate figures — 89 GPM at 10 ft of head, dropping to 50 GPM at 15 ft — illustrate a core principle of ejector pump sizing: the higher the pump has to lift wastewater, the less volume it can move per minute. This is why simply picking "the bigger pump" isn't always right — what matters is matching the pump's performance curve to your specific vertical lift distance and expected flow demand. A pump undersized for your home's head requirements will struggle and wear out faster; one that's oversized wastes money without meaningful benefit.

 

Continuous Duty Rating: A Meaningful Distinction

 

The M267 is explicitly rated for continuous duty cycle operation, meaning the motor is engineered to handle sustained running without the rest periods some pumps require to avoid overheating. This matters for higher-demand ejector applications — a busy basement bathroom and laundry room combined, for instance — where the pump may need to run more frequently than a typical single-fixture setup.

 

Minimum Sump Pit Diameter: A Real Installation Constraint

 

The listed 18" minimum sump pit diameter is a genuine constraint to plan around — the basin needs sufficient interior clearance for the pump, float switch, and proper water circulation. If you're retrofitting an ejector system into an existing basement, confirming adequate space for an 18"+ basin is one of the first things to check before ordering equipment.

 

State Code Variation: Solids Size Restrictions

 

The product description notes it "may be used in those states where codes do not restrict solids size in effluent systems" — a useful reminder that plumbing code requirements for ejector pumps vary by jurisdiction. Some local codes have specific solids-passing requirements or restrictions that go beyond the pump's mechanical capability. Our technicians stay current on Illinois and local Chicago-area suburb code requirements to ensure your installation is fully compliant.

 

Shared Durability Features

 

Like other Zoeller sewage models, the M267 includes:

 

  • ASTM Class 25 cast iron construction for the switch case and pump housing
  • Non-clogging vortex impeller with metal inserts for durability
  • Oil-filled, hermetically sealed motor with automatic reset thermal overload protection
  • Carbon and ceramic shaft seal for long-term reliability
  • UL Listed and CSA Certified, confirming independent safety and performance verification

 

Is the M267 Right for Your Application?

 

Consider the M267 over the M264 if your ejector system needs to handle:

 

  • A greater vertical lift distance to reach the sewer connection
  • Multiple fixtures or higher-than-typical flow demand
  • Continuous or frequent operation, such as a heavily used basement bathroom

 

Professional Installation and Sizing Matters

 

Given the head/flow tradeoffs and minimum pit size requirements involved, professional sizing assessment is essential before installation. Our licensed plumbers will:

 

  1. Calculate your system's actual vertical lift (head) requirement
  2. Confirm sump pit sizing meets the 18" minimum diameter requirement
  3. Verify code compliance for your specific municipality
  4. Install with proper venting, check valve, and code-compliant electrical connection
  5. Test performance against your home's real fixture demand

 

Frequently Asked Questions

 

How do I know if I need the M264 or the M267?
It depends on your vertical lift distance and fixture demand; our technicians calculate your system's specific head requirement to recommend the right pump rather than guessing based on horsepower alone.

 

What happens if my sump pit is smaller than 18"?
The basin may need to be replaced or resized to accommodate proper pump operation and clearance; our plumbers can assess your existing pit during a consultation.

 

Does "continuous duty" mean the pump runs all the time?
No — it means the motor is engineered to handle sustained operation without needing rest periods to avoid overheating, which is valuable for higher-demand applications, not that the pump runs continuously under normal use.

 


 

Founded in the family basement in 1939, Zoeller Pump Company is one of the oldest family-owned water pump manufacturers in North America. Headquartered in Louisville, KY, we proudly excel with fourth-generation leadership and an expanding workforce.

 

Over the past seven decades, Zoeller Pump Company has established itself as a dependable leader in the wastewater industry. Through continuous research and development, we are always improving our products and processes to provide the highest possible quality to our loyal customers and end users.

 

This dependability is backed by a family commitment to add value for our customers and provide genuine support before, during, and after a sal

 

With multiple locations throughout North Shore and Northwest suburbs of Chicago, Illinois, Emergency Plumbing offers promt and professional plumbing services.

 

Are you looking for a reliable plumber near me in the Arlington Heights, Bannockburn, Barrington, or surrounding areas?

 

Our local plumbing company offers expert services, catering to all your needs. Whether you're in the heart of Buffalo Grove, the serene streets of Deerfield, or require an emergency plumber in Des Plaines or Elk Grove Village, we are here to help. Our plumbing contractors are well-versed in the unique plumbing systems of Glencoe, Glenview, Hawthorn Woods, and Highland Park.

 

For those in Highwood, Hoffman Estates, or the quaint town of India Creek, our team guarantees prompt and efficient service.

 

Residents of Inverness, Kildeer, Lake Bluff, Lake Forest, and Lake Zurich can also rely on our expertise. We extend our services to Long Grove, Mettawa, Lincolnshire, Mount Prospect, Mundelein, Northbrook, and Palatine.

 

Need a plumber in Prospect Heights, Ravinia, RiverWoods, Rolling Meadows, Vernon Hills, Wauconda, Wheeling, Wilmette, or Winnetka? Look no further! As a trusted plumbing contractor, we ensure that your plumbing issues are solved quickly and efficiently, keeping your home or business running smoothly.

 

PRICE LIST, plumber near me, north shore, northwest suburbs of Chicago, Illinois, clogged drain, sewer, hot water, emergency plumbing, installation, repair, Smart Housing Systems, hvac, contractor, license plumber



REQUEST A QUOTE 📩

Name:
E-mail *:
Phone *:
Product *:
Your area *:
Message *:
Add a file (15MB max.):
Security code *:


↓ OR ↓



⏰ Dispatcher support 24/7

📞 224-754-1984